Avaya 03-300430 User Manual
SNI-BD (SNI Circuit Pack)
Issue 1 June 2005
2099
113
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 13 over the
packet path.
packet path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot
13. Use display errors to find any SNI-BD errors and use the
display alarms command to determine whether the errors have
on-board alarms. Then, follow the repair procedures for the SNI-BD
as described in the Maintenance manual.
on-board alarms. Then, follow the repair procedures for the SNI-BD
as described in the Maintenance manual.
2. Use display errors to check the error log for other SNI circuit
packs with SNI-PEER Error Type 2049. If other SNI circuit packs have
SNI-PEER Error Type 2049 errors, replace the SNI in slot 13.
Replacing an SNI may be service interrupting. See
SNI-PEER Error Type 2049 errors, replace the SNI in slot 13.
Replacing an SNI may be service interrupting. See
on page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 2049 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first.
3. Replace the SNI being tested.
4. Replace the SNI in slot 13.
114
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 14 over the
packet path.
packet path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot
14. Use display errors to find any SNI-BD errors and use the
display alarms command to determine whether the errors have
on-board alarms. Then, follow the repair procedures for the SNI-BD
as described in the Maintenance manual.
on-board alarms. Then, follow the repair procedures for the SNI-BD
as described in the Maintenance manual.
2. Use display errors to check the error log for other SNI circuit
packs with SNI-PEER Error Type 2305. If other SNI circuit packs have
SNI-PEER Error Type 2305 errors, replace the SNI in slot 14.
Replacing an SNI may be service interrupting. See
SNI-PEER Error Type 2305 errors, replace the SNI in slot 14.
Replacing an SNI may be service interrupting. See
on page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 2305 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first.
3. Replace the SNI being tested.
4. Replace the SNI in slot 14.
Table 754: TEST #767 Packet Neighbor Link Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
7 of 12