Communication Manager Maintenance-Object Repair Procedures
2112 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
PASS
No problems associated with this test are detected on the SNI.
0
NO
BOARD
No board was detected by the test.
1. Check that board is properly translated and inserted.
2. Run the test again. If it fails, reset the board. An SNI should be reset 
instead of reseating the circuit pack. The reset board command 
should almost never be used on an SNI. It may be necessary to use 
reset board if the SNI circuit pack gets into a mode where it cannot 
communicate with software. If an SNI with active errors and alarms is 
reset, the errors and alarms may take a while to come back, therefore 
reset board can mask real problems.
3. Run the test again. If it fails, the ID chip on board may be bad. 
Replace the board and retest.
Table 756: TEST #989 SNI Fiber Out of Frame Query  (continued)
Error
Code
Test
Result
Description / Recommendation
 6 of 6