Communication Manager Maintenance-Object Repair Procedures
2126 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Failed
Yes
At least two terminals rejected the firmware as invalid. As a 
result, the download was aborted to avoid problems with any 
further terminals. Check the Reason Codes of the failed 
terminals in the list to find the reason why the download failed 
(
Completed
Yes
The scheduled download has completed either due to all 
terminals in the range of extensions having completed or due 
to the stop timer.
Disabled
Yes
An Active schedule was disabled with the disable 
firmware station-download command. After an active 
schedule is disabled, the Schedule state remains Active until 
all currently active terminal downloads have completed.
No Image
Yes
The download was stopped because there was no firmware 
image present in memory.
Restart
Yes
The download was stopped due to a system restart. You must 
schedule a new download for any Aborted terminals.
Sys Fail
Yes
The download was stopped due to a system error.
Sys Occ
No
The download has been suspended due to the system’s 
occupancy level. The schedule resumes when the occupancy 
level drops to a safe level.
Dnld Timeout
Yes
While the scheduled download was running, two or more 
consecutive terminals failed to respond to the download 
process.
Table 762: Reason Codes for status firmware station-download command
Reason
Code
Status
Description
1
ABRT
The firmware image that was noted in the change firmware 
station-download form has disappeared. The download schedule had to 
be stopped.
2
ABRT
The terminal could not be downloaded due to a discrepancy relating to the 
maximum number of downloads allowed.
 1 of 2
Table 761: Schedule States of status firmware station-download command (continued)
State
Schedule
Done?
Description
 2 of 2