STRAT-3 (Stratum-3 Clock)
S8700 MC
 only
The Digital Synchronization Network Plan (PUB 60110) specifies a hierarchy of synchronization 
nodes consisting of Strata 1 to 4, where the public network’s sole Stratum-1 clock is the most 
accurate. Release 5r and later systems support both Stratum-3 and -4 operations. See 
on page 2146 for details on Stratum-4 operation.
A Stratum-3 clock derives its timing from two DS1 references connected to a Stratum-3 or better 
source. The Stratum-3 clock provides a holdover of at least 24 hours should both DS1 
references fail. (After 24 hours, the Stratum-3 clock still provides service but its accuracy may 
be degraded). The Digital Synchronization Network Plan (PUB 60110) requires that the 
Stratum-3 clock have duplicated components.
The Stratum-3 clock can be configured with only one DS1 input if one of the Clock Input cards is 
removed. Also, the Stratum-3 clock can free run (use its internal clock without using DS1 inputs, 
if both Clock Input cards are removed).
Only a TN780 Tone-Clock circuit pack recognizes and supports a Stratum-3 clock and its alarm 
signals. (The TN780 Tone-Clock circuit pack is also backward- compatible with a TN768 
Tone-Clock circuit pack.) The Stratum-3 clock may be connected to a non IPSI PN where a 
TN780 Tone-Clock circuit pack resides. The Stratum-3 clock should never be connected to an 
IPSI connected PN.
The only operation that software can perform is a query of the alarm leads. The only recovery 
action that can be performed on a catastrophic failure of the Stratum-3 clock is using the local 
oscillator on the active TN780 Tone-Clock circuit pack. Neither software nor the TN780 
Tone-Clock circuit pack can request additional information about the health of the Stratum-3 
clock other than the information provided by the alarm leads. Furthermore, neither the software 
nor the TN780 Tone-Clock circuit pack can request that the external clock switch references, 
change configuration, disable/enable, initialize, and so forth.
In the system, the Stratum-3 clock has been implemented as an external which follows the 
specification in PUB 60110 for Stratum 3. The only external Stratum-3 clock that is supported is 
the Telecom Solutions Digital Clock Distributor for Customer Premise Timing (DCD-CPT) 
Stratum-3 clock. 
how the Stratum-3 hardware configuration provides clock and alarm signals to the TN780 
Tone-Clock circuit pack(s). The reference DS1 facilities connect directly to the Stratum-3 clock 
for timing purposes, but the DS1 data may be routed into the switch by using a Y connector 
(H-600-274 G1 for the 50-pin DS1 end or H-600-274 G2 for the 15-pin DS1 end).
For more information about installing a Stratum-3 clock, refer to Installing the Avaya S8700 
Media Server with the Avaya G600 Media Gateway, the Avaya MCC1 Media Gateway, or the 
Avaya SCC1 Media Gateway (Library CD)
.
MO Name
Alarm Level
Initial SAT Command to Run
Full Name of MO
STRAT-3
MAJ
test synchronization
Stratum-3 clock
STRAT-3
MIN
test synchronization
Stratum-3 Clock