Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
2188 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
k. Error 6103: an application alarm occurred on the standby server. See note (
) to diagnose
the error using the Aux Data.
l. Error Types 6002, 6003, 6102, and 6103: the aux-data value points to the MO that the
error or alarm is logged against. The following table lists possible aux-data values and their
associated MOs. Locate the Error Log entry for the indicated MO and follow the instructions
for that error.
associated MOs. Locate the Error Log entry for the indicated MO and follow the instructions
for that error.
m. Aux Data:
and notes give causes and recommendations for each Aux Data value
for Error Type 605.
Aux Data
Implicated MO
4137
PKT-INT
16384
PROCR
16385
MEM-BD
16389
DUPINT
16391
SW-CTL
16392
H-ADAPTR
16397
R-MEDIA
16398
DISK
Table 781: SYSTEM Error 605 Aux Data, Failure of Planned Interchange
Aux
Data
Data
See
Note
Note
Explanation
1352 (
) 1
Standby SOH "non-functional"
1353 (
) 1
Standby SOH not "functional"
1355 (
) 1
Handshake Communication with standby server is down
1356 (
) 1
Memory Shadowing not enabled
1357 (
) 1
Standby memory not refreshed
1358 (
) 2
Mass Storage System was in use
1359 (
3
PKT-INT link migration failed
1360 (
) 1
Interchange failed
1 of 2