Communication Manager Maintenance-Object Repair Procedures
2190 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
d. Aux Data 1361, 1370, 1400, 1401: consult SW-CTL service documentation. Test SW-CTL 
on both carriers with the long test sequence. Follow repair instructions for any failures. 
Once every test of both SW-CTLs passes, try the interchange again.
e. Aux Data 1371, 1402, 1403, 1404, 2500: ensure that the standby server is refreshed, then 
try the interchange again.
f. Aux Data 1372: examine alarm log to determine which of the PKT-INT or SYSAM circuit 
packs has a minor alarm against it. Consult the section in this chapter for that circuit pack.
g. Aux Data 1379: run test duplication-interface long, and follow instructions for 
any test that does not pass.
Error Log Entries and Test to Clear Values
The Aux Data field may be 0 or the return code from a bad software call, and the following 
examples in no way exhaust the possibilities. Often, two errors are logged at the same time for 
each problem.
Notes:
a. Error Type 0: run the Short Test Sequence first. If all tests pass, run the Long Test 
Sequence. Refer to the appropriate test description and follow the recommended 
procedures.