Avaya 03-300430 User Manual

Page of 2574
TBRI-TRK (Trunk-Side ISDN BRI Channel)
Issue 1 June 2005
2233
 
1120
ABRT
The trunk-side ISDN-BRI facility is in the ISDN out-of-service/far-end 
state.
1. Try to change the service state via Test #256 (Service State 
Audit test). Then retry this test. However, the trunk may be in the 
out-of-service/far-end state due to problems at the far-end 
switch. If that is the case, no remedial action can be taken at this 
end.
1122
ABRT
There is no test line number for the far-end switch.
1. Check the Trunk Group Administration screen.
1123
ABRT
There is no Feature Access Code administration for this Facility test.
1. Check the Dial Plan and Feature Administration forms.
S8300
 / 
G700
:
1412
ABRT
This test does not execute on a G700 media gateway.
2012
None
2000
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2035
ABRT
The call has timed out, perhaps because of a lack of system 
resources.
1. Wait 1 minute and try again.
2. If the test continues to abort, escalate the problem. 
2036
2037
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2038
2039
ABRT
A problem occurred while trying to read the test data.
1. Wait one minute and then try again.
2. If the test aborts again in the same manner, there is a serious 
internal problem. If so, escalate the problem.
Table 800: Test #258 ISDN Test Call  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 6