Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
2236 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2213
ABRT
The call has timed-out, perhaps because of a lack of system
resources.
resources.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2214
ABRT
Call terminated by unexpected disconnect.
1. Wait one minute and then try again.
2215–
2219
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2220
ABRT
Call terminated prematurely.
1. Wait one minute and try again.
2221–
2226
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2227
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2042
FAIL
This is the main purpose of the test. The comparison of the data
sent with the data received indicates a loss of integrity on the
communications path.
sent with the data received indicates a loss of integrity on the
communications path.
1. The trunk should be taken out-of-service and the quality of the
ISDN trunk-side BRI facility should be investigated. The
investigation should include an in-depth analysis of the facility
including the transmission facility and any external equipment
such as DACs, CSUs, etc.
investigation should include an in-depth analysis of the facility
including the transmission facility and any external equipment
such as DACs, CSUs, etc.
PASS
The call worked. A test pattern was sent and received properly; the
communications path is OK if the synchronous test call command was
entered. An in-depth analysis of the ISDN trunk-side BRI facility
including the transmission facility and any external equipment such as
DACs, CSUs, and others should take place if the bit and block error
rates are not acceptable.
Table 800: Test #258 ISDN Test Call (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
6 of 6