Communication Manager Maintenance-Object Repair Procedures
2256 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
h. Error Type 1025: Processor/Tone-Clock circuit on-board maintenance has detected one or
more clock slips, timing differences between its internal reference source and the
synchronization signal provided by the master Tone-Clock. Although no clock slip errors are
expected during normal operation, both manual and automatic interchanges of Tone-Clock
circuit, synchronization references, and PNCs could result in clock slip counts.
synchronization signal provided by the master Tone-Clock. Although no clock slip errors are
expected during normal operation, both manual and automatic interchanges of Tone-Clock
circuit, synchronization references, and PNCs could result in clock slip counts.
If Error Type 1281 also is logged for the same Tone-Clock circuit, it is related to this problem
and should be corrected first. Otherwise, continue with the following procedure.
and should be corrected first. Otherwise, continue with the following procedure.
1. Use test tone-clock location, and examine the results of Test #149 to see if slip
errors still appear. If no new slip errors are reported, and if these errors are not causing a
TDM-CLK alarm, they may be ignored. Use test tone-clock location long
clear to clear the errors.
TDM-CLK alarm, they may be ignored. Use test tone-clock location long
clear to clear the errors.
2. Otherwise, enter display errors, and follow corrective procedures for any other
TDM-CLK, TONE-BD, SYNC, DS1C-BD, EXP-INTF, SNC-BD, and SNI-BD errors
logged, except for those in
logged, except for those in
3. If Error Type 1025 errors persist, see
i. Error Type 1281:
the Processor/Tone-Clock circuit has detected a loss of timing signal from
the system’s synchronization reference. The Processor/Tone-Clock circuit has switched
synchronization references.
synchronization references.
1. Resolve any errors logged against the SYNC or STRAT-3 MOs.
2. See
on page 2143 maintenance, if the error is not
resolved by step 1.
Error Type 1282:
the TN2182 tone-clock was synchronized to a DS1 facility and that the
reference frequency provided by the DS1 drifted beyond a range that could be tracked by
the TN2182. Therefore the TN2182 is no longer synchronized to that DS1 reference. If a
second DS1 is available, the tone-clock may be synchronized to that reference. If no
secondary DS1 reference is available, the tone-clock will run off of its internal clock. This
may result in slips being reported by the tone-clock and every DS1 facility.
the TN2182. Therefore the TN2182 is no longer synchronized to that DS1 reference. If a
second DS1 is available, the tone-clock may be synchronized to that reference. If no
secondary DS1 reference is available, the tone-clock will run off of its internal clock. This
may result in slips being reported by the tone-clock and every DS1 facility.
Table 807: Error Log Entries for Slip Errors
Circuit Pack Name
Error Log Name
Error Log Entry for Slips
DS1 Interface
DS1-BD
3073 to 3160
Expansion Interface
EXP-INTF
2305
Switch Node Interface
SNI-BD
1537
Tone-Clock
TDM-CLK
1025
UDS1 Interface
3073 to 3160
DS1C Circuit Pack
DS1C-BD
3329