Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2258 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
c. If not, replace the standby Tone-Clock circuit. See 
If this clears the error, the problem has been resolved.
5. Replace the EI circuit pack for the active PNC.
6. If the problem is still not cleared and the IPSI or Tone-Clock circuit pack reported in the 
error log has not yet been replaced, replace it. See 
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one 
test may also clear errors generated from other tests in the sequence.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
Reset 
Board 
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
SAKI Reset test (#53) (
X
D
Clock Health test (#46) (
X
X
ND
Control Channel Loop-Around test (#52) (
X
X
ND
Tone Generator Crosstalk test (#90) (
)
X
ND
Tone Generator Transmission test (#40) (
X
X
ND
Tone Generator Audit/Update test (#41) (
)
X
X
ND
TDM bus Clock Circuit Status Inquiry (#148)
X
X
ND
TDM bus Clock Slip Inquiry test (#149) (
X
X
ND
TDM bus Clock PPM Inquiry test (#150)
X
X
ND
TDM bus Clock Parameter Update test (#151)
X
X
ND
Board Type Check test (#574)
X
X
ND
Standby Reference Health Check test (#651) (
)
X
ND