Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2272 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each appropriate test’s description, and follow its recommended 
procedures.
257 (
57473
57474
513 (
57392
DS1 Tie Trunk 
Seizure (#136)
MAJ
MIN
2
769 (
)
57393
DS1 Tie Trunk 
Seizure (#136)
MAJ
1025
DS1 Tie Trunk 
Seizure (#136)
MIN
WRN
OFF
test trunk grp#/mem# r 2
1281
Conference Circuit 
Test (#7)
MIN
WRN
ON
test trunk grp#/mem# l r 4 
1537
NPE Crosstalk Test 
(#6)
MIN
WRN
ON
test trunk grp#/mem# l r 3 
1793 (
)
test board location long 
2305 (
50944
DS1 Tie Trunk 
Seizure (#136)
MAJ
OFF
2562 (
)
16665
2817 (
52992
3840 (
)
Any
Port Audit and 
Update (#36)
1. 
For TN767B vintage 8 or 9 circuit packs, a failure of Test #136 causes a subsequent failure of 
Test #7. Test #136 is part of the short sequence and generates off-board alarms. Test #7 is part 
of the long sequence and generates on-board alarms. Before entering busyout, release, reset or 
test board long commands, check the vintage number of the circuit pack with 
list 
configuration board location
. If it is TN767B vintage 8 or 9, do not use the above 
commands until you ensure sure that Test #136 passes via test board short. Otherwise, 
extraneous on-board alarms may be generated.
2. 
*Major or Minor alarms on this MO may have been downgraded to Warning based on the values 
in 
set options
.
Table 814: DS1 Tie Trunk Maintenance Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off 
Board
Test to Clear Value
 2 of 2