Avaya 03-300430 User Manual

Page of 2574
TIE-DS1 (DS1 Tie Trunk)
Issue 1 June 2005
2273
 
b. Error Type 1: the DS1 Interface circuit pack or media module detects a hardware error on 
the DS1 tie trunk. This error can be caused by incompatible translations. Make sure the 
parameters administered on the DS1 circuit pack or media module form match those 
administered on the far-end switch. See Administrator Guide for Avaya Communication 
Manager, 03-300509
 for 
details.
The Aux Data field indicates the following hardware Error Types:
If every administration parameter between the switch and the far end match and these 
errors continue to recur, follow normal escalation procedures.
c. Error Type 15: this is a software audit error that does not indicate any hardware 
malfunction. Run the short test sequence, and investigate associated errors (if any).
d. Error Type 18: the DS1 tie trunk has been busied out with busyout trunk grp#/mem#
No calls can be made on this trunk except for the Facility Access Test call. See 
Administrator Guide for Avaya Communication Manager, 03-300509.
e. Error Type 19: the far end may be out-of-service, or the Electronic Tandem Network may 
be busied out.
f. Error Type 130: the circuit pack or media module has been removed or has been insane for 
more than 11 minutes. To clear the error, reinsert or replace the circuit pack or media 
module.
g. Error Type 257: the DS1 Interface circuit pack or media module detects a hardware error 
on the DS1 tie trunk. The trunk cannot communicate with the far end because it is unable to 
interpret digits sent from the far-end switch. The Aux Data field indicates the following:
Check with the far-end switch or operating company for proper trunk connection.
h. Error Type 513: the DS1 Interface circuit pack or media module detects a hardware error 
on the DS1 tie trunk. The trunk is in-service/active and waiting for an “on-hook” from the 
far-end switch. No calls can be routed over the trunk while it is in this state. Aux Data 57392 
indicates no external release on PBX disconnect. Check with the far-end switch or 
operating company for proper trunk connection.
57476
On-hook before wink
57477
On-hook before ready to receive digits
57485
Wink too short for valid signal
57487
The timer expired while waiting for an off-hook signal from the far end as 
a response at end-of-digits dialing. Check the far-end switch for related 
problems.
57473
The rotary dial rate is below 8 pulses per second.
57474
The rotary dial rate is above 12 pulses per second.