TIE-TRK (Analog Tie Trunk)
Issue 1 June 2005
2315
 
1006
ABRT
(TN497 circuit pack only.) The port is in the out-of-service state. The test 
cannot be run.
1. Retry the command once the port is in service.
2100
ABRT
Could not allocate the necessary system resources to run the test. This 
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
This test passed. Translation information was successfully updated on 
the circuit pack. If the trunk is busied out, the test does not run but returns 
a PASS (except on TN439 and TN497).
1. If signaling troubles are reported, verify translation information for 
this port.
(Non-TN497 circuit packs only.) If the trunk is busied out, the test 
does not run, but it does return PASS.
2. To verify that the trunk is in-service, enter status trunk to verify 
that the trunk is in-service. If the trunk is in-service, no further action 
is necessary. If the trunk is out-of-service, continue to Step 2.
3. Enter release trunk to put trunk back into in-service.
4. Retry the test command.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct. Translate the board, if 
necessary.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port.
Table 831: Test #36 Audit Update Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2