Avaya 03-300430 User Manual

Page of 2574
VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 1 June 2005
2489
 
Note:
Note:
2561–2668 is a range of reserved numbers for future applications. 2570 currently 
represents an SNMP socket failure.
n. Error Type 2817–2819: Congestion Query test (#600) failed.
The Error Types correspond to the descriptions:
1. See 
on page 2499 for Error Code 3601 ABRT and FAIL 
information.
o. Error Type 3073: Remote Socket Control Link (RSCL) or Link Status test (#601) failed. This 
failure can be due to:
This circuit pack
The packet bus
The packet interface circuit pack.
p. Error Type 3330: critical failure in Packet bus interface.
Below, Error Types correspond to descriptions.
1. Attempt to clear the alarm (reset board location).
2. If alarm persists, replace circuit pack.
2817
Every buffer exhausted.
2819
Utilized buffers exceed threshold.
If:
Then:
Active buffers exceed threshold,
VAL enters congested state.
If:
Then:
RSCL disconnects at link level
Link fails
Link cannot be reconnected quickly
Switch raises MINOR alarm
If the switch detects:
Then it:
1 error,
Resets circuit pack.
2 errors in 15 minutes,
Raises MINOR alarm.