Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2552 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack or media module. It is executed as part of the long test 
sequence only for the Tone-Clock circuit pack and DS1 interface circuit packs, and for the 
MM710 DS1 Interface Media Module. Other common circuit packs and media modules can be 
reset with the reset board location command which also executes this test.
Table 912: Test #53 SAKI Sanity Test 
Error
Code
Test
Result
Description / Recommendation
None
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABRT
S8700 | 8710
 / 
S8500
:
Wrong circuit pack configuration to run this test. This error applies only to 
DS1 interface circuit packs. It means the DS1 interface circuit pack is 
providing timing for the system and, therefore, it cannot be reset without 
major system disruptions.
1. If the circuit pack needs to be reset, then set synchronization to 
another DS1 interface circuit pack or the Tone-Clock circuit pack and 
try again. See 
G700
:
If this is a G700 media gateway system, and the MM710 DS1 interface 
Media Module under test is providing timing for the platform, it cannot be 
reset without major platform disruptions 
Note: For this type of system the sync timing source is local to the G700.
1. If the MM710 Media Module needs to be reset, then set the 
synchronization timing source to another MM710 DS1 interface Media 
Module located in the same G700 and retest. See 
 in Maintenance Procedures (03-300192).
1015
ABRT
Port is not out-of-service.
1. Busy out the circuit pack or media module.
2. Execute command again.
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1
FAIL
The circuit pack or media module failed to reset.
 1 of 2