XXX-BD (Common Port Circuit Pack/Media Module)
Issue 1 June 2005
2555
 
1018
ABRT
There are not any translated ports on the circuit pack, or if there are ports, 
then none are administered to have "neon."
1. Verify that there are ports administered on the circuit pack. If no ports 
are administered, no further action is required.
2. Verify that you have neon sets connected (Avaya sets that may be 
neon sets are 500 and 2500 series, also some non-Avaya may also be 
neon sets). If no neon sets are connected to the circuit pack, the test 
continues to abort, but no further action is required.
3. If there are no neon sets connected to the circuit pack, at least one 
port needs to be translated with neon. To check if a port is translated 
with neon, use the display port location command to 
determine the station extension of any station on this circuit pack. Use 
the display station extension to determine if the port is 
administered with neon. The field "Message Waiting Indicator:" must 
be set to "neon" for at least one of the administered ports. If this field is 
not administered to "neon" the test continues to abort. This is 
acceptable because not all stations have neon lamps on their analog 
terminals. If none of the terminals have neon lamps, the test continues 
to abort, but no further action is required.
4. Retry the command again.
5. Retry the command at 1-minute intervals a maximum of 5 times.
6. If the test continues to abort, look for RING-GEN errors in the Error 
Log. If an ABRT 1008 occurs for this test on other circuit packs as well, 
then the ringing generator may be defective. If it does not occur on 
port test 48 for ANL-16-L, all four ring phases are in use.
7. Retry the command again.
G700
:
1412
ABRT
This test does not execute on a G700 Media Gateway.
2000
ABRT
Response to the request was not received within the allowable time period.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Table 913: Test #220 Neon Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3