Avaya 03-300430 User Manual

Page of 2574
AC-POWER
Issue 1 June 2005
335
 
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order shown. By clearing error codes associated with the Battery and 
Battery Charger Query test (#5), you may clear errors from other tests in the testing sequence.
Note:
Note:
The following tests apply to J58890CE, J58890CF, and J58890CH.
AC Power Query Test (#78)
This test queries either the server’s watchdog (via an Ethernet or USB interface) or an MCC 
PN’s Maintenance circuit pack for status of the cabinet’s AC power.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Battery & Battery Charger Query test (#5)
X
X
ND
AC Power Query test (#78)
X
X
ND
Power Unit Query test (carrier E) (#127)
X
X
ND
Power Unit Query test (carrier D) (#127)
X
X
ND
Power Unit Query test (carrier A) (#127)
X
X
ND
Power Unit Query test (carrier B) (#127)
X
X
ND
Power Unit Query test (carrier C) (#127)
X
X
ND
Emergency Transfer Query test (#124)
X
X
ND
Cabinet Temperature Query test (#122)
X
X
ND
External Alarm Lead Query test (#120)
X
X
ND
Analog Ring Generator Initialization test (#117)
X
X
ND
Analog Ring Generator Query test (#118)
X
X
ND