ALARM-PT (Alarm Port)
S8700 | 8710
 / 
S8500
 / 
S8300
The Alarm Port MO provides on-board maintenance for an analog line port that is administered 
as an external device alarm port. Tests are provided to verify the analog line ports ability to 
detect an external device alarm. The related MO, 
on page 1246, is used for the off-board external device alarm.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. Error Type 15 is a software audit error that does not indicate any hardware malfunction. 
Run the short test sequence, and investigate errors.
c. Error Type 130 indicates that the circuit pack or Media Module was removed or has been 
insane for more than 11 minutes. To clear the error, reseat or replace the circuit pack or 
Media Module
MO Name in Alarm Log Alarm
Level
Initial Command to Run
Full Name of MO
ALARM-PT
MIN
test port location l
Alarm-Port
ALARM-PT
WRN
test port location sh
Alarm-Port
Table 109: ALARM-PT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0 (
0
Any
Any
Any
test port location sh r 1
15 (
Any
Audits and Updates 
(#36)
18
0
busyout station 
extension
WRN
OFF
release station extension
130 (
)
None
WRN
ON