Avaya 03-300430 User Manual

Page of 2574
ANL-16-L (16-Port Analog Line)
Issue 1 June 2005
399
 
Loop-Around Test (#161)
This test checks the on-board transmission capabilities of the NPE, the codec, and the battery 
feed chip of the analog port.  The test passes if the signal measured by the Tone Detector is 
within acceptable limits.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).  This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct.  Enter list config
and resolve any problems.
2. If the board was found to be correctly inserted in step 1, enter 
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port.  If 
not, verify that a valid board is inserted.
Table 117: Test #48 Station Present Test  (continued)
Error 
Code
Test
Result
Description / Recommendation
 3 of 3
Table 118: Test #161 Loop-Around Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available.  The port 
may be busy with a valid call.
1. Use display port location to determine the station extension.
2. Use status station to determine the service state of the port. If 
the port is active, wait until it is idle.
3. Retry the command at 1-minute intervals up to 5 times.
 1 of 4