Avaya 03-300430 User Manual

Page of 2574
ANL-LINE (8-Port Analog Line)
Issue 1 June 2005
405
 
Hardware Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first.  If every test passes, run the long test 
sequence.  Refer to each appropriate test’s description, and follow its recommended 
procedures.
Table 119: 8-Port Analog Line Error Log Entries
Error 
Type
Aux
Data
Associated Test
Alarm 
Level
On/
Off 
Board
Test to Clear Value
0
Any
Any
Any
test port location sh r 1
40960
40975
40977
None
15 (
Any
Audits and Updates 
(#36)
18
0
busyout station 
extension
WRN
OFF
release station extension
130 
)
None
WRN
ON
test port location sh
257 
)
Station Present test 
(#48)
WRN
OFF
test port location sh r 3
513
Battery Feed test (#35)
MIN  
WRN
1
1. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set options.
ON
test port location sh r 2
769 (
Loop Around & 
Conference (47)
test port location l r 3
1025
NPE Crosstalk test (#6)
MIN 
WRN
ON
test port location l r 3
1281
)
1793
)