ANL-LINE (8-Port Analog Line)
Issue 1 June 2005
423
 
1008
ABRT
Could not allocate a ringing circuit for one of the following reasons: 
Every ringing circuit is active.
The ringing generator is defective.
It is incorrectly wired.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error 
Log.  If an ABORT 1008 occurs for Test #48 on other circuit packs as 
well, then the ringing generator may be defective or incorrectly wired.  
If it does not occur on other ports, then that circuit pack is currently 
using all four ringing phases.
1018
ABRT
The test was disabled by administration. The default for the Test field is y
thus, you may want to determine why this field has been set to “n” on this 
station (this may be due to the ringing application Test #48, which can be 
customer or terminal disturbing).
1. To enable the test for a particular station, enter change station 
extension and set the Test field to y.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
System resources required to run this test are not available.  Either a 
system allocation to get information about the port or to put the port into a 
service state failed or the attempt to put the port in connection with a tone 
source failed (this could be a Tone-Clock problem).  The Tone-Clock and 
Tone Detectors could be having a communication problem.  For example, 
the companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.