Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
488 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
h. Error Type 2562 - 2566: the ASAI message is not transmitted because the transmit buffer
for the ASAI link is full, causing the link to be flow-controlled. Frequent or persistent
occurrence of these events may indicate a hardware problem or traffic overload on the
PKT-CTRL, the signaling link, or the ASAI adjunct. Follow the repair procedures issued by
the manufacturer of the adjunct. If these attempts fail, re-engineering of the traffic on the
PKT-CTRL, signaling link, or adjunct may be necessary.
occurrence of these events may indicate a hardware problem or traffic overload on the
PKT-CTRL, the signaling link, or the ASAI adjunct. Follow the repair procedures issued by
the manufacturer of the adjunct. If these attempts fail, re-engineering of the traffic on the
PKT-CTRL, signaling link, or adjunct may be necessary.
i. Error Type 2567: This version of ASAI is not supported. Check the software version that is
running on the ASAI adjunct.
j. Error Type 2568: The adjunct identification is invalid. Check the vendor ID or software
running on the ASAI adjunct.
k. Error Type 3329: the point-to-point signaling link to the endpoint went down, except when
the link goes down because either a system technician has busied out the PKT-CTRL or the
PKT-BUS, or they have failed. This error raises an alarm against the endpoint or adjunct.
Execute test station extension short and note the results of the Signaling Link
PKT-BUS, or they have failed. This error raises an alarm against the endpoint or adjunct.
Execute test station extension short and note the results of the Signaling Link
Status Test (#626). If this test fails, follow the repair procedure for Test #626. The alarm is
retired when the signaling link is re-established to the endpoint or adjunct.
retired when the signaling link is re-established to the endpoint or adjunct.
l. Error Type 3584 - 3839: The switch software logs certain ASAI cause values. The cause
value is determined from the following formulas:
- If the error type is greater than 3712, then the ASAI cause value is equal to the error type
minus 3712. The switch sent this value to the adjunct.
- If the error type is less than 3712, then the ASAI cause value is equal to the error type
minus 3584. The adjunct sent this value to the switch.
on page 489 contains a description of the various ASAI
cause values and recommended system technician actions associated with the cause
value.
value.
m. Error Type 3841 - 4095: The switch software logs certain ASAI cause values. The cause
value is determined from the following formula:
- If the error type is greater than 3968, then the ASAI cause value is equal to the error type
minus 3968. The switch sent this value to the endpoint.
- If the error type is less than 3968, then the ASAI cause code is equal to the error type
minus 3840. The endpoint sent this value to the switch.