Avaya 03-300430 User Manual

Page of 2574
ASAI-PT
Issue 1 June 2005
495
 
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first.  If every test passes, run the long test 
sequence.  Refer to each appropriate test’s description, and follow its recommended 
procedures.
b.  Error Type 1: Level 1 Status inquiry fails or when the BRI circuit pack detects that Level 1 
has been deactivated on the port.  The Aux Data field contains one of the following values:
Refer to the repair procedures for Test #621.
Table 149: ASAI-PT Error Log Entries 
Error
Type
Aux
Data
Associated 
Test
Alarm Level
ASAI-
PORT
On/Off 
Board
Test to Clear Value
0 (
)
0
Any
Any
Any
test port location sh r 1
1 (
)
(a)
Level 1
Status 
inquiry 
(#621)
MAJ
1
1. Major and Minor alarms may be downgraded to warning alarms based on the value used in set options.
OFF
test port location sh r 2
0
none
(b)
ON
1537 (
) 46210
CRC Error 
counter 
(#623)
MAJ
OFF
3841 (
) 46208
None
3844 (
46223
None
3845 (
) 46211
None
3846 (
) TEI
None
Blank
This indicates that the Level 1 Status inquiry failed.
32773
This is a message from the ASAI-Line circuit pack indicating Level 1 has been 
deactivated.