System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented. By clearing error codes associated with the ASAI Port 
Local LAN Looparound test (#618), you may also clear errors generated from other tests in the 
testing sequence.
BRI Port Local LAN Loop-Around Test (#618)
This test is destructive.
This test verifies the connectivity of a BRI port across the LAN Bus and executes only if the port 
is out-of-service.  The test aborts if calls associated with the port are in-progress.  Failures of 
this test indicate either on-board faults associated with the ASAI-PT hardware on the circuit 
pack or problems with the LAN Bus, which is used to form connectivity between the switch and 
the ASAI-PT.
The dotted lines in 
loop-around test is performed across the packet bus for the D channel.
Table 150: System Technician-Demanded Tests: ASAI-PT
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1. D = Destructive, ND = Nondestructive
ASAI Port Local LAN Looparound test (#618)
X
D
Level 1 Status Inquiry test (#621)
X
X
ND
CRC Error Counter test (#623)
X
ND
Layer 1 Transmission Error Counter test (#624)
X
ND
Receive FIFO Overflow Error Counter test (#625)
X
ND
Clear Error Counters (#270)
X
X
ND