Communication Manager Maintenance-Object Repair Procedures
524 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Signaling Link Board Check (#643)
This nondestructive test checks the health of the ATM TN230X trunk circuit pack’s hardware.  
The test runs on a periodic or scheduled basis, during initialization testing, and upon demand.
Note:
Note:
The board-level maintenance is handled independently of the ATM-CES 
signaling link maintenance, raising the possibility of inconsistent states.
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
8
FAIL
The TN230X circuit pack is not in-service.
1. Check the Error Log for ATM-TRK errors and resolve any using 
PASS
The ATM TN230X circuit pack is in-service.