Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
572 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
XYZ
FAIL
A device on the circuit pack is failing.  There is at least one bad DSP on the 
board.  Values are as follows:
The X value indicates the number of talker DSPs
Y indicates the number of listener DSPs
Z indicates the number of Echo Canceler DSPs that have failed the 
test.
1. Run the tests for the active Tone-Clock in the PN that contains the 
indicted ATM-EI circuit pack to verify that dial-tone is supplied.
2. If the Tone-Clock is healthy, repeat the short test on the ATM-EI board.
3. If this test continues to fail, replace the ATM-EI circuit pack.
XYZ
PASS
The test passed for some or all DSPs depending on XYZ values.  XYZ 
indicates the number of talker, listener and echo-canceler DSPs for which 
the test passed, respectively.  In the DSPs that passed the test, the test tone 
was correctly detected by the DSP Listener and by tone-detector for the 
DSP Talkers on both buses, and the Echo Canceler DSPs are working 
properly.
0
NO
BOARD
No board was detected by the test.
1. Check the Error Log for wrong board (Error Type 125) or no board 
(Error Type 131).  Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted.  If so, check 
for hyperactivity (Error Type 1538).  If hyperactive, use reset board 
location
.
3. Run the test again.  If it fails, the circuit pack could be bad.  Replace 
the circuit pack and retest.
Table 185: ATM Board DSP Test (#1293)  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3