ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 June 2005
625
 
22
High-level Path 
Alarm 
Indication 
Signal: 
HP_AIS
The payload is invalid.
1. Make sure the ATM switch port (or a MUX port, if present 
between ATM switch and the ATM-TRK board) is the same as 
the ATM-TRK circuit pack’s cable interface.
2. Run test board location.
3. If Test #1259 fails with Error Code 22, connect a fiber 
back-to-back in a looped mode (one strand of fiber connecting 
the transmit transceiver to the receive transceiver of the board) 
and see if the amber LED flash goes away.
4. If it does the problem is off-board.
5. If the amber LED continues to flash, replace the circuit pack.
23
High-level path 
Remote defect 
Indicator: 
HP_RDI
The far end is detecting a major problem with the signal that this 
board is transmitting.  The transmitted payload is invalid.
1. Make sure the ATM switch port (or a MUX port, if present 
between ATM switch and the ATM-TRK board) is the same as 
the ATM-TRK circuit pack’s cable interface.
2. Run test board location.
If Test #1259 fails with Error Code 23, connect a fiber 
back-to-back in a looped mode (one strand of fiber connecting 
the transmit transceiver to the receive transceiver of the board) 
and see if the amber LED flash goes away.
If it does the problem is off-board.
If the amber LED continues to flash, replace the circuit pack.
24
Loss of cell 
delineation 
(LCD)
On board ATM framer chip is not able to frame cells based on the 
cell header.
1. Reset the board with reset board location.
2. If the error persists, replace the board.  
27
SIGCON_DO
WN ATM 
switch high 
level signal.
The board cannot communicate with the ATM switch.
1. Busyout the board (busyout board location).
2. Test the board (test board long location).
3. If Test #1260 fails, replace the board.
4. If Test #1260 passes, make sure the ATM address on both the 
S8700 Multi-Connect and the ATM switch sides are the same 
for this board.
5. If the address is the same, change the port on the ATM switch 
side.
6. If the error is resolved, the problem is on the ATM switch port.
Table 209: Error type 1281 Aux Data and repair procedures  (continued)
Aux 
Data
Alarm 
Description
Repair procedure
 3 of 3