Communication Manager Maintenance-Object Repair Procedures
646 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2000
ABRT
Test timed out.
1. If the ATM-TRK circuit pack is in standby, reset the board and run the 
test again after the ATM-TRK circuit pack is inserted.
2. Examine the Error Log for Error 1218 (bad DSP).
3. Run the test again.
2100
ABRT
Could not allocate required system resources.
1. Retry the command at 1-minute intervals up to 5 times.
2302
ABRT
Inconsistent uplink message from the ATM-TRK circuit pack.
2500
ABRT
Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
2752
ABRT
Circuit pack not a TN2305A/2306A.
XYZ
FAIL
There is at least one bad DSP on the board.  The X value indicates the 
number of bad talker DSPs, Y indicates the number of bad listener DSPs 
and Z indicates the number of bad echo canceler DSPs.
1. Test the Active Tone-Clock in the PN that contains the ATM-TRK circuit 
pack for dial-tone.  Repair as needed.
2. Repeat the short test on the ATM-TRK circuit pack.
3. If the test continues to fail, check for service-affecting MINOR alarms.  
If a MINOR alarm is raised for Error Type 2817 or 1818, replace the 
circuit pack.
4. If a WARNING alarm is raised, this is a non-service-affecting error, and 
the circuit pack can still process calls.
XYZ
PASS
The test passed for some or all DSPs.  XYZ indicates the number of talker, 
listener, and echo-canceler DSPs for which the test passed (the rest of the 
DSPs were skipped).  The X value indicates the number of good talker 
DSPs, Y indicates the number of good listener DSPs, and Z indicates the 
number of good echo canceler DSPs.
Table 220: ATM Board DSP Test (#1293)  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3