Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
648 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1003
ABRT
Could not allocate a tone receiver.  Too few Tone Detectors installed or 
Tone Detectors out-of-service.
1. Identify and correct any TTR-LEV (TTR Level) errors listed in the Error 
Log.
2. Resolve any TONE-PT (Tone Generator) errors listed in the Error Log.
3. Retry the test up to 5 times at 1-minute intervals a maximum.
1962 
ABRT
Every TALKER DSP is busy.
2000
ABRT
Test timed out.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate required system resources
1. Retry the command 5 times at 1-minute intervals.
2302
ABRT
Inconsistent uplink message from the ATM-TRK circuit pack.
1. Retry the command up to 3 times at 1-minute intervals.
2752
ABRT
The circuit pack in this location is not a TN2305A/2306A.
1–8,
None
FAIL
ATM-TRK circuit pack writing on unauthorized TDM time slots.  The error 
code indicates the number of TALKER DSPs that are at fault.  These 
DSPs cannot be used again until this test of the ATM DSP test (#1293) 
tells the circuit pack to use them again.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the failure persists, replace the circuit pack.
1-8
PASS
ATM-TRK circuit pack not talking to un-authorized time slots on the TDM 
bus.  The error code indicates the number of TALKER DSPs tested.
Table 221:  ATM Crosstalk Test (#1298)  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2