AUX-TRK (Auxiliary Trunk)
Issue 1 June 2005
665
 
1004
ABRT
The port was seized by a valid call during the test.  The test has been 
aborted.
1. Use display port location to determine the trunk group/member 
number of the port.  Use status trunk to determine the service 
state of the port.  If the port is active, wait until it is idle.
2. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7
FAIL
The conference capabilities of the port failed.
1. If no service problems exist on the port, continue to use the port until 
the circuit pack can be replaced.
129
FAIL
The reflective 404-Hz tone test failed, no transmission was detected to or 
from the port.  The problem may be off-board.
1. To make sure the problem is on-board, disconnect the port from the 
auxiliary equipment and retry test.
2. If the test fails, replace the circuit pack.  Otherwise, if the test passed 
after disconnecting the port from the auxiliary equipment, the problem 
is off-board.  Check the wiring and connections to the auxiliary 
equipment and retry the test after reconnecting the port to the auxiliary 
equipment.  If the test fails, check the auxiliary equipment.  See the 
preceding procedure for a failure with Error Code 7.
Note:
Note:
If the Looparound and Conference test fails for every port on a 
circuit pack, a -5 Volt power problem is indicated.  If a TN736 or 
TN752 power unit circuit pack is present, the 631DB AC power 
unit or the 676B power unit may be defective.  The system may 
contain either a TN736 or a TN752 power unit circuit pack OR a 
631DB power unit, but not both types of power units.  To 
investigate power problems, see 
Table 225: Test #33 Looparound and Conference  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 4