Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
668 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Audit Update Test (#36)
This test sends updates of the auxiliary trunk port translation for every port on the Auxiliary
Trunk circuit pack that has been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No response message is
expected from the circuit pack once it receives translation updates. The port translation data
includes:
Trunk circuit pack that has been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No response message is
expected from the circuit pack once it receives translation updates. The port translation data
includes:
●
Trunk type
●
DTMF time slot
●
Termination R/RC
●
Gain, high/low
●
End-to-end signaling, tone, and pause duration
●
Trunk state, idle/active/unavailable
●
Companding mode (A-law or mu-law)
Table 226: Test #36 Audit Update Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1006
ABRT
Port is in out-of-service state as a result of being busied out. This audit
cannot be run.
cannot be run.
1. Retry the command once the port is in service (release port
location has been run).
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
This test passed. Translation information was successfully updated on the
circuit pack.