Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
698 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1005
ABRT
This test is not valid for this type of translation. Ports administered as “ASAI”
or “ADJK” cannot run this test, because the B channels associated with the
port are not used by ASAI or Avaya Adjunct Links. This is a normal
condition.
2000
ABRT
Response to the test was not received from the BRI-LINE circuit pack
within the allowable time period.
within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the
other ports are idle. Reset the circuit pack by issuing the busyout
board location and reset board location.
board location and reset board location.
2. If this result occurs again, replace the circuit pack.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2100
ABRT
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2103
ABRT
The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1, 2
FAIL
As stated previously, this test runs a TDM Loop Around test on each
B channel. This indicates that the loop around failed on one of the channels.
Error Code 1 indicates that the TDM Loop Around test failed on B1. Error
Code 2 indicates that the TDM Loop Around test failed on B2.
7, 8
FAIL
As stated previously, this test runs a Conference Circuit test on each
B channel. A failure here indicates that one of these conference tests
failed; Error Code 7 means that the test failed on B1; Error Code 8 means
that the test failed on B2.
B channel. A failure here indicates that one of these conference tests
failed; Error Code 7 means that the test failed on B1; Error Code 8 means
that the test failed on B2.
1. If the test fails repeatedly, attempt to reset the circuit pack if the other
ports on the circuit pack are idle. Reset the circuit pack by issuing the
busyout board location and reset board location.
busyout board location and reset board location.
2. If the test fails again, replace the circuit pack.
PASS
The BRI Port Local TDM Loop Around test has passed.
Table 233: Test #619 BRI Port Local TDM Loop Around (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 2