Avaya 03-300430 User Manual

Page of 2574
BRI-SET, Various Adjuncts
Issue 1 June 2005
729
 
1187
ABRT
The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD, 
BRI-PORT, or BRI-SET.
a. If this error type is present for BRI-SET only, then release the station 
via release station.
b. If this error type is present for BRI-PORT and BRI-SET, then release 
the port via release port location and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then 
release the circuit pack via release port location and run the 
test again.  If the error is present for BRI-SET only, then release the 
circuit pack via release port location and run the test again.  
If the error is present for both BRI-BD and BRI-PORT, then release 
the circuit pack via release board location and run the test 
again.
Note:
Note:
When you release the circuit pack, you release every port 
associated with it.  If certain ports still need to be busied out, 
use busyout port location to busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
2012
ABRT
Internal system error.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2068
ABRT
The endpoint has rejected the switch sent application message.  This 
indicates that the endpoint does not support the ISDN-BRI Management 
and Maintenance Procedure for Endpoint Service messages.
1. Use change station extension  and change the MIMs Supported 
field to n.
Table 246: Test #629 BRI Layer 3 Query  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 4