1187
ABRT
The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD, 
BRI-PORT, or BRI-SET.
a. If this error type is present for BRI-SET only, then release the station 
via release station.
b. If this error type is present for BRI-PORT and BRI-SET, then release 
the port via release port location and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, use 
release port location to release the circuit pack, and run the 
test again.  If the error is present for both BRI-BD and BRI-PORT, 
use release board location to release the circuit pack, and 
run the test again.
Note:
Note:
When you release the circuit pack, you release every port 
associated with it.  Use busyout port location if ports 
still need to be busied out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
2012
ABRT
Internal system error.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
PASS
The switch has successfully executed the BRI station audits.