Avaya 03-300430 User Manual

Page of 2574
CARR-POW (Carrier Power Supply)
Issue 1 June 2005
781
 
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented.  By clearing error codes associated with the Battery & 
Battery Charger Query 
test (#5), you may also clear errors generated from other tests in the 
sequence.
Notes:
 section for a description of this test.
 section for a description of this test.
 section for a description of this test.
 section for a description of this test.
 section for a description of this test.
 section for a description of this test.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Battery & Battery Charger Query test (#5) (
X
X
ND
AC Power Query test (#78) (
X
X
ND
OLS Query test (carrier E) (#127)
X
X
ND
OLS Query test (carrier D) (#127)
X
X
ND
OLS Query test (carrier A) (#127)
X
X
ND
OLS Query test (carrier B) (#127)
X
X
ND
OLS Query test (carrier C) (#127)
X
X
ND
OLS Recycle Carrier test (#126)
D
Emergency Transfer Query test (#124) (
X
X
ND
Cabinet Temperature Query test (#122) (
X
X
ND
External Alarm Lead Query test (#120) (
X
X
ND
 Analog Ring Generator Initialization test (#117) (
)
X
X
ND
Analog Ring Generator Query test (#118) (
X
X
ND