DIG-LINE (Digital Line)
Issue 1 June 2005
949
 
S8300
 / 
G700
For the MM712 Media Module, the status of the EPF is sent uplink. Possible conditions are 
EPF-on-ok, EPF-off, and EPF-no-load.
Table 325: Test #17 Station (Digital) Audits Test 
Error 
Code
Test 
Result
Description / Recommendation
1
ABRT
Switchhook audit timed out.
2
ABRT
ID request fails, health bit returned from voice terminal is bad.
1. Make sure voice terminal is connected, and repeat the test.
2. If test fails, replace voice terminal and repeat test.
3
ABRT
S8700 | 8710
 / 
S8500
: The EPF/PTC has detected an overcurrent condition.
1. For a TN754 vintage 13 or earlier Digital Line circuit pack, use test 
location long
If Test #11 passes, then the EPF/PTC condition was cleared. Rerun 
the Short Test Sequence.
If Test #11 does not pass, follow the repair procedures described for 
Test #11.
S8700 | 8710
 / 
S8500
 / 
S8300
:
2. Look for Error Type 769 logged against DIG-LINE and follow the 
procedures in the additional information. If any additional problems are 
found, rerun the test.
4
ABRT
Internal system error
1. Resolve any outstanding circuit pack or media module maintenance 
problems.
2. Retry the command at 1-minute intervals up to 5 times.
5
ABRT
Ringer update aborted due to station being in ready-for-service or 
out-of-service state.
 1 of 2