Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
950 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
6
ABRT
This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error is present, the release the port via release station
extension.
extension.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required for this test are not available.
1392
ABRT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either display port (the
display shows that the port is a TTI port) or list config (the display
shows a “t” for the port).
2. If either list config or display port indicate that the port is not
a TTI port, escalate the problem. If both commands indicate that the
port is a TTI port, the abort is correct, and no action is necessary.
port is a TTI port, the abort is correct, and no action is necessary.
2000
ABRT
Response to the test was not received in the allowable time period.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Station Audits passed. This Digital Port circuit pack or media module is
functioning properly.
functioning properly.
1. If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
Table 325: Test #17 Station (Digital) Audits Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 2