Communication Manager Maintenance-Object Repair Procedures
954 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 0
:
 Run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its recommended procedures.
b. Error Type 1
Aux Data 57408: No tip ground is detected on an outgoing call.
Aux Data 57476:
 
Rotary Dial before Wink.
Aux Data 57477:
 
Rotary Dial pulse too early.
Aux Data 57485:
 
Wink too short for a valid signal.
Aux Data 57487:
 
PBX could not get “loop close” signal.
The DS1 Interface circuit pack detected a hardware fault. These errors will cause the Dial 
Tone test (#314) to run and are only considered a problem if the Dial Tone test fails (in which 
case Error Type 1025 will also show up). In this case, the trunk may be put in the 
ready-for-service state (shown as “disconnected” by the status command), which allows 
only incoming calls. Run the Dial Tone test (#314) and follow the procedures.
1025
DS1 CO Dial 
Tone Seizure 
(#314)
MIN
WRN
2
OFF
test trunk grp#/mem# r 2
1281
Conference 
Circuit test (#7)
MIN
ON
test trunk grp#/mem# l r 4
1537
NPE Crosstalk 
test (#6)
MIN
ON
test trunk grp#/mem# l r 3
1793 (
test board location l
2049 (
57473
57474
57475
2305 (
50944
2562 (
)
16665
2817 (
)
52992
3840 (
)
Port Audit and 
Update (#36)
1. This alarm is raised when the 
Base Tone Generator 
field is 4 (Italy) on the System-Parameter 
Country screen. This alarm is MINOR unless 75% or more trunks in this trunk group are out of service, then 
the alarm is upgraded to a MAJOR alarm.
2. Major alarms may be downgraded to Warning alarms based on the value used in set options.
Table 326: DS1 DIOD Trunk Error Log Entries  (continued)
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
 2 of 2