DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 June 2005
957
 
1001
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors. Use status health to determine if the system is 
experiencing heavy traffic.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present, or some Tone 
Detectors may be out of service.
1. Enter list measurements tone-receiver to see information 
about the system’s tone receivers.
2. Resolve any TTR-LEV errors.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the test at 1-minute intervals up to 5 
times.
1004
ABRT
The port has been seized by a user for a valid call. Use status trunk to 
determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1020
ABRT
The test did not run due to a previously existing error on the specific port or 
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit 
pack and attempt to diagnose the already existing error.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
Table 328: Test #6 NPE Crosstalk Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3