Communication Manager Maintenance-Object Repair Procedures
962 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1004
ABRT
The port has been seized by a user for a valid call. Use status trunk to 
determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABRT
Test failed due to incompatible configuration administered in trunk group 
screen.
1. Look at the Trunk Group administration screen and see if the trunk is 
incoming only, port 24 on a DS1 Interface with common 
control-channel signaling, or an automatic CO type such as FX. Under 
any of these conditions this is a normal abort.
1018
ABRT
Test has been disabled via administration.
1. Verify that the Maintenance Tests field on the Trunk Group screen is 
set to n. To enable the test, enter change trunk-group x where 
x” equals the number of the trunk group to be tested, and change the 
Maintenance Tests field on the screen to y.
2. Repeat the test.
1020
ABRT
The DS1 Interface circuit pack is out-of-service.
1. Look for UDS1-BD errors in the Hardware Error Log. If present, see 
2. Retry the command.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Table 331: Test #314 DS1 CO Dial Tone Seizure Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3