Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
960 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Port Audit and Update Test (#36)
This test sends port-level translation data from switch processor to the DS1 Interface circuit 
pack to assure that a trunk’s translations are correct. Translation updates include the following 
data: trunk type (in/out), dial type, timing parameters, and signaling bits enabled. The port audit 
operation verifies the consistency of the current state of trunk kept in the DS1 Interface circuit 
pack and in switch software.
FAIL
The NPE of the tested port did not conference the tones correctly. This will 
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port can correctly conference multiple connections. User-reported 
troubles on this port should be investigated by using other port tests and by 
examining station, trunk, or external wiring.
Table 329: Test #7 Conference Circuit Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3
Table 330: Test #36 Port Audit and Update Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
2100
ABRT
Could not allocate the necessary system resources to run this test.
FAIL
Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2