Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
994 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Table 343: Test #135 Internal Loop-Around Test 
Error 
Code
Test 
Result
Description / Recommendation
2012
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present, or some Tone 
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 
times.
1004
ABRT
Received an incoming call on a port of the DS1 circuit pack during the test.
1. Enter busyout board location to put every trunk on the DS1 
circuit pack into the out-of-service state.
2. Retry the command at 1-minute intervals up to 5 times.
1015
ABRT
Ports on DS1 Interface circuit pack have not been busied out.
1. Enter busyout board location to put every trunk on the 
DS1circuit pack into the out-of-service state.
2. Retry the command.
1039
ABRT
The DS1 Interface circuit pack is providing timing for the system. 
Therefore, it cannot be reset without major system disruption.
1. If the DS1 Interface circuit pack needs to be tested, set the 
synchronization reference to another DS1 Interface circuit pack or to 
the Tone-Clock circuit using the following command sequence: 
a. Enter disable synchronization-switch
b. Enter set synchronization location
c. Enter enable synchronization-switch
 1 of 3