Avaya 03-300430 User Manual

Page of 2574
DS1-BD (DS1 Interface Circuit Pack)
Issue 1 June 2005
995
 
2000
ABRT
The test was aborted. Response to the test was not received within the 
allowable time period. This may be due to hyperactivity. Error type 1538 in 
the error log indicates hyperactivity. The hyperactive circuit pack is out of 
service and one or more of the following symptoms may be exhibited.
The DS1-BD tests (such as Tests 139 and 140) are aborting with 
error code 2000.
The tests run on the ports of this circuit pack are returning a no board 
result.
busyout or a release command has no affect on the test results.
list config command shows that the circuit pack and the ports 
are properly installed.
When hyperactivity occurs, the circuit pack is isolated from the system, and 
all of its trunks are placed into the out-of-service state. The system will try to 
restore the circuit pack within 15 minutes. When no faults are detected for 
15 minutes, the DS1 interface circuit pack is restored to normal operation. 
Every DS1 interface trunk is then returned to the in-service state. 
Hyperactivity is often caused by the associated facility. In such a case, faults 
(such as slips, misframes, or blue alarms) would be entered in the error log. 
In addition, many hardware errors would be logged against the associated 
trunk circuits. If the facility is OK and the error recurs after 15 minutes, 
escalate this problem.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
DS1 Interface circuit pack failed the Internal Looparound test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the DS1 Interface circuit pack is a TN767, enter list 
measurement ds1-log location to read the error seconds 
measurement. Otherwise, skip this step.
3. Verify that both of the DS1 link’s endpoints are assigned with the same 
signaling mode, framing mode, and line coding.
4. Check the physical connectivity of DS1 Interface circuit packs and 
cable.
5. Contact T1 Network Service to diagnose remote DS1 endpoint.
6. If 
 are OK and the problem recurs, escalate the problem.
Table 343: Test #135 Internal Loop-Around Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3