DS1-BD (DS1 Interface Circuit Pack)
Issue 1 June 2005
997
 
S8700 MC
This test is also used to maintain the 120A CSU module and the 401A T1 sync splitter. The 
CSU module, when combined with the functionality provided by the TN767E circuit pack, 
provides functionality equivalent to an external standalone ESF T1 CSU The 401A T1 sync 
splitter, when combined with the functionality provided by the TN767E circuit pack, allows an 
ATM switch to derive its timing off a T1 facility connected to the S8700 Multi-Connect’s 
DS1circuit pack.
If a TN767E circuit pack detects certain I-CSU/T1 sync splitter hardware errors, it will notify the 
maintenance subsystem. When the subsystem receives notification of the error, it executes this 
Loss of Signal Inquiry test. The test, in addition to querying for a Loss of Signal alarm condition, 
will also query the TN767E board to confirm the error. A Minor or Warning alarm will be raised 
depending on the severity of the error. The trunks on the board may be taken out of service if 
the error is deemed serious.
If a Loss of Signal alarm and an I-CSU/T1 sync splitter error co-exist, the Loss of Signal alarm 
condition takes priority, and the board and all of its trunks are put in the out-of-service state. 
However both errors will be logged.
When the maintenance subsystem receives notification that the ICSU/T1 sync splitter hardware 
error condition no longer exists, maintenance will restore the board and all trunks to their 
previous service state if the alarm can be cleared (no other errors or Loss of Signal alarm exist).
Table 344: Test #138 Loss of Signal Alarm Inquiry Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Internal system error
 2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.