Bosch ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 8.0  
Alarm Link Software 
EN | 41 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
•  Program the Call Back Telephone Number in 
Locations 159 to 174 (refer to Section 11.9 on 
page 51). 
•  Disable Option 1 in Location 180 (refer to Section 
8.2 Alarm Link Options on page 41). 
The control panel is set so the client controls when a 
remote connection is established. 
To dial the remote computer: 
Press and hold [6] until two beeps sound on the 
remote codepad. 
8.1.2 
Remote Connection without Callback 
Verification 
Remote connect without callback verification is 
useful if you must perform Upload/Download 
functions from multiple locations.  
There are two methods to disable callback 
verification. Using this feature reduces the security of 
the control panel. 
Method One 
Method one allows you to call the control panel from 
any remote location without the control panel calling 
back to the computer to establish a link. When using 
this method, the customer cannot initiate a modem 
call by holding down [6].  
To program method one: 
1.  Program Locations 159 to 174 for the Call Back 
Telephone Number to 0 (refer to Section 11.9 on 
page 51). 
2.  Select Option 1 and disable Option 2 in Location 
180 (refer to Section 8.2 Alarm Link Options on 
page 41). 
The control panel allows a connection of the first call 
without calling the remote computer back. 
Method Two 
Method two allows you to program a callback 
telephone number so that the customer can still 
initiate a modem call when required. When you call 
the control panel from a remote location using the 
computer, the control panel does not call back the 
remote computer to establish a link.  
To program method two: 
1.  Program the Call Back Telephone Number in 
Locations 159 to 174 (refer to Section 11.9 on 
page 51). 
2.  Select Option 1 and disable Option 2 in Location 
180 (refer to Section 8.2 Alarm Link Options on 
page 41)
The control panel allows a connection of the first call 
without calling back the remote computer to make 
contact. It allows the customer to initiate a modem 
call by holding down [6]. 
8.1.3 
Remote Connection with Callback 
Verification 
Remote connect with callback verification offers the 
highest degree of data security by incorporating a 
two-level security check. 
The first level is provided because the Installer Code 
and the Subscriber ID Number must match those of 
the control panel. The sec level of security exists 
because the control panel calls the programmed 
callback telephone number to establish the valid 
connection.  
To program the control panel for remote 
connection with callback verification: 
1.  Program the Call Back Telephone Number in 
Locations 159 to 174 (refer to Section 11.9 on 
page 51). 
2.  Select Options 1 and 2 in Location 180 (refer to 
Section 8.2 Alarm Link Options on page 41). 
8.1.4 Direct 
Connection 
The direct connect feature gives the installer a simple 
method to program the ICP-CC488 Control Panel 
using a portable computer. Because telephone lines 
and modems are not required, programming of the 
control panel is easily completed in min. 
To use the direct connect feature, connect the CC808 
Direct Link Cable between the correct serial port on 
your IBM or compatible computer and the auxiliary 
module socket on the control panel. 
To use the direct connect feature, it is not necessary 
to select Option 1 Location 180. The direct connect 
feature ignores this option. 
8.2 Alarm 
Link 
Options 
Location
180 
Enable upload/download using Alarm Link 
Enable Alarm Link call back  
Terminate Alarm Link connection on alarm 
8 Reserved 
When programming these locations, you can select 
any of four options. You can select any combination 
of the options by programming a single value. 
Calculate this value by adding the option bit 
numbers together. Refer to Section 7.3 Programming 
Option Bits
 on page 36 for more information. 
1 – Enable Upload/Download Using Alarm Link 
Select this option to use the CC816 Alarm Link 
Software to program the control panel remotely. The 
control panel does not respond to the Alarm Link 
Software if this option is not selected. Refer to Section 
8.0 Alarm Link Software
 on page 40 for more 
information.