Bosch ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 14.0  
Zone Information 
EN | 62 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
The ICP-CC488 Control Panel performs lockout 
differently than other control panels because only the 
first zone to activate an alarm is locked out. All other 
zones that are activated during the same Siren Run 
Time are reset when the sirens are reset. This 
prevents an intruder from activating all zones and 
waiting for the sirens to stop before re-entering the 
premises. 
Example 
All zones are programmed for both lockout siren and 
dialer. Zone 1 is activated, followed by all other 
zones, which activates the sirens and causes the dialer 
to report to the base station receiver. Zone 1 is the 
only zone that stops reporting to the base station 
receiver because the first activated zone is locked out. 
The remaining zones continue to report if they are 
activated again. 
Use Location 379 to set the number of times the siren 
is allowed to activate before it is locked out (refer to 
Section 14.4 Swinger Shutdown Count for Siren on page 
64). Use Location 380 to set the number of times the 
dialer is activated before lockout takes effect (refer to 
Section 14.5 Swinger Shutdown Count for Dialer on page 
64). ). 
2 – Delay Alarm Reporting 
Select this option to allow the reporting of alarms on 
selected zones to be delayed so that a user can enter 
a code to cancel alarms that are not required to 
report. All sounding devices (horn speaker, strobe, 
and bell outputs) operate as soon as the alarm occurs, 
but the dialer does not operate until the delay time 
programmed in Locations 474 and 475 expires (refer 
to Section 17.6 Delay Alarm Reporting Time on page 78). 
4 – Silent Alarm 
Select this option to program a zone as silent. A silent 
zone does not activate the horn speaker, bell, strobe, 
or EDMSAT outputs. The dialer and all other 
programmable outputs function according to the 
parameters programmed for the zone. 
8 – Sensor Watch 
Sensor watch allows the control panel to recognize 
when detection devices might have stopped working. 
This feature monitors the operation of a zone over 
the time period programmed in Locations 476 and 
477 (refer to Section 15.5 Zone Status – Sensor Watch 
Reports on page 78).  
This value specifies how many 24-hour periods a 
zone can remain continuously sealed before it 
registers as a Sensor Watch fault. The number of 
hours required to fulfill these 24-hour periods is 
calculated only when the system is disarmed. Every 
time the system is armed in the AWAY Mode, STAY 
Mode 1, or STAY Mode 2, the Sensor Watch Timer 
pauses its count. The Sensor Watch Timer continues 
its count the next time the system is disarmed. 
Program Locations 389 and 390 to 0 to disable 
Sensor Watch Reports (refer to Section 15.5 Zone 
Status – Sensor Watch Reports 
on page 66). 
Example 
If the Sensor Watch Time is programmed for 2 days 
and the premises is armed for 12 hours and disarmed 
for 12 hours each day, it takes 4 days before a zone 
can register a Sensor Watch fault. 
14.3.6 
Keyswitch Zone Options 
Table 51 on page 62 lists the options available to 
Keyswitch Zones. If you program a zone as a 
keyswitch input (Zone Type 11), program the 
selected Keyswitch Zone options in the location 
normally used for Zone Options 1. Keyswitch zones 
report as User Code 16. 
Table 51:  Keyswitch Zone Options 
 
Option 
Description 
Latching arm and disarm in AWAY Mode 
Latching arm in AWAY Mode 
Latching disarm from AWAY Mode, STAY 
Mode 1, or STAY Mode 2 
Latching arm and disarm in STAY Mode 1 
Latching arm in STAY Mode 1 
Latching disarm from STAY Mode 1 or STAY 
Mode 2 
Momentary arm and disarm in AWAY Mode 
Momentary arm In AWAY Mode 
10 
Momentary disarm from AWAY Mode, STAY 
Mode 1, or STAY Mode 2 
12 
Momentary arm and disarm in STAY Mode 1 
13 
Momentary arm in STAY Mode 1 
14 
Momentary disarm from STAY Mode 1 or 
STAY Mode 2 
0 – Latching Arm and Disarm in AWAY Mode 
The system is armed or disarmed from AWAY Mode 
when using the latching keyswitch input. 
1 – Latching Arm in AWAY Mode 
The system is armed in AWAY Mode when using 
the latching keyswitch input. Disarming the system is 
not permitted from the Keyswitch Zone. 
2 – Latching Disarm from AWAY Mode, STAY Mode 
1, or STAY Mode 2 
The system is disarmed from AWAY Mode, STAY 
Mode 1, or STAY Mode 2 when using the latching 
keyswitch input. Arming the system is not permitted 
from the Keyswitch Zone. 
4 – Latching Arm and Disarm in STAY Mode 1 
The system is armed or disarmed in STAY Mode 1 
when using the latching keyswitch input. Arming and 
disarming the system in AWAY Mode is not 
permitted from the Keyswitch Zone.