Zone Information 
EN | 64 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
When isolating 24-Hour Zones, the system 
automatically sends a Zone Bypass Report when the 
zone is selected to be isolated. All non-24-Hour zones 
send a Bypass Report only when the system is 
armed. 
If you do not want the system to report Zone Bypass 
Reports, program Locations 385 and 386 to 0 (refer 
to Section 15.3 Zone Status – Bypass Reports on page 65). 
4 – Forced Arming Allowed 
If this option is selected, the system can be armed 
with the zone unsealed. If this option is not selected, 
the system does not allow the User Code holder to 
arm the system until the zone is sealed or manually 
isolated. Refer to Section 3.11 Isolating Zones on page 
17 for more information. 
8 – Zone Restore Report 
If this option is selected, the zone sends Restore 
Reports when the zone is restored. If this option is 
not selected, the zone does not send Restore Reports 
when the zone is restored. 
If a non-24-Hour zone is not restored when the 
system is disarmed, the system automatically sends a 
Zone Restore Report for that zone. All 24-Hour 
zones send a Zone Restore Report only when the 
zone is restored. 
14.3.8 Zone 
Report 
Code 
If you want the control panel to transmit Zone Alarm 
Reports, program this location as 1. If not, program 
this location as 0. 
14.3.9 Zone 
Dialer 
Options 
By default, a zone reports only to Receiver 1. Table 
53
 on page 64 lists the reporting options for the zone. 
Table 53:  Zone Dialer Options 
 
Option 
Description 
No report required 
Receiver 1 
2 Receiver 
Receiver 1 and Receiver 2 
Receiver 2 only when Receiver 1 fails 
 
14.4  Swinger Shutdown Count for Siren 
Location 
379 
Default 
1 to 15 
Number of times siren operates until lockout 
Location 379 determines the number of times the 
sirens can be activated before lockout options take 
effect. This location has no effect unless you program 
at least one zone for lockout siren. Refer to Section 
14.3.5 Zone Options 1
 on page 61 to program zones 
for lockout siren.  
Only alarms activated from zone inputs can 
decrement the Swinger Shutdown Counter. Alarms 
such as Codepad Panic, Access Denied, and other 
system alarms do not affect the Swinger Shutdown 
Count. 
When the sirens are operating, the Swinger 
Shutdown Counter is decremented only by the first 
zone that activated the alarm. Any other zones 
activated during Siren Run Time do not affect the 
counter.  
When the Swinger Shutdown Count is reached, all 
zones that were activated are locked out according to 
their individual lockout settings. 
Example 
All eight zones are programmed for lockout siren 
with a Swinger Shutdown Count of 3. If Zone 1 
activates an alarm, the Swinger Shutdown Count is 
decremented by one after the end of Siren Run Time 
to a swinger shutdown count of 2.   
After the Siren Run Time is reset from the previous 
alarm, Zone 2 activates an alarm and activates the 
sirens. After the sirens are reset, the swinger 
shutdown count is decremented again to 1.  
If Zone 3 also activates an alarm after the sirens are 
reset from Zone 2, the Swinger Shutdown Count is 
decremented to 0, which locks out all three zones 
from sounding the sirens until the system is reset.   
At this point, the Swinger Shutdown Count for Sirens 
is reset to 3 and the process of swinger shutdown for 
remaining zones begins again until all zones are 
locked out. 
 
If the ICP-CC488 Control Panel is 
partitioned, the Swinger Shutdown Count 
for Siren applies to both Area 1 and 
Area 2. 
 
14.5  Swinger Shutdown Count for Dialer 
Location
380 
Default 
1 to 15 
Number of times dialer operates until lockout 
Location 380 determines the number of times the 
dialer can be activated before lockout options take 
effect. This location has no effect unless you program 
at least one zone for lockout dialer. Refer to Section 
14.3.5 Zone Options 1
 on page 61 to program zones 
for lockout dialer. 
Only alarms activated from zone inputs can 
decrement the Swinger Shutdown Counter. Alarms 
such as Codepad Panic, Code Retries, and other 
system alarms do not affect the Swinger Shutdown 
Count. 
When the dialer is online, its counter is decremented 
only by the first zone that activated the alarm. Any 
other zones activated while the dialer is online do not 
affect the counter.