Quadra-Fire 7051-158B User Manual

Page of 58
December 6, 2011
7051-158B
Page  45
EDGE 60 Pellet Fireplace
Non-combustible 
Hearth Extension
Clean-out 
Cover
Tee
Wall Thimble
Support 
Bracket
every 60 in. 
(1524mm)
12 in. 
(305mm) 
minimum
Termination 
Cap
Flashing 
0 in. (0mm) to Standoff
6 in. (152mm) 
minimum 
Firestop
Flashing
Termination 
Cap
6 in. 
(152mm) 
Min.
Non-combustible 
Hearth Extension
1 in. (25mm) 
Minimum
*See Note 
12 in. 
(305mm) 
Minimum
0 in. (0mm) to 
Standoff
J.  Vertical - Interior - Typical Installation
K.  Through the Wall & Vertical - Exterior
Figure 44.1
Figure 44.2
We recommend a minimum of 60 inches (1.52m) verti-
cal, however above the eave is preferred. 
Both installations are approved for mobile home instal-
lations.  Must use 3 or 4 inch (76mm to 102mm) “L” 
or “PL” Listed pellet venting or Listed double wall pipe 
and Quadra-Fire Outside Air Kit in all installations.  
Single wall pipe is approved for residential installa-
tions only.
*NOTE: Clearance to combustibles are for 1 inch 
(25mm) clearance approved pellet pipe.  If pellet pipe 
has a 2 inch or 3 inch (51mm or 76mm) air clearance 
to combustibles, increase the clearance from rear 
standoff accordingly to meet pipe manufacturer clear-
ance requirements