7.2.5  Replacing filter element
"H" (Push & Clean
System)
During the following work, ensure 
that dust is not unnecessarily 
spread around, Wear a P2 breath-
ing mask.
CAUTION! In the case of asbestos 
abatement wear additional single-
use clothing.
Never use the vacuum cleaner 
without a filter.
32
27
36
38
ø
ø
ø
ø
A
A
A
A
1.  Switch  off  the  vacuum 
cleaner  and  pull  the  mains 
plug out of the socket.
2.  Open  the  retaining  clamps 
(A)  and  remove  the  up-
per  section  of  the  vacuum 
cleaner.



Removing the filter element:
3.  Using the enclosed tool (C), 
turn the filter holder (D) anti-
clockwise and remove it.
4.  Carefully  remove  the  filter 
element.
5.  Clean  the  filter  seal  (B). 
Check it for damage and re-
place it if necessary. 
6.  Place  the  protective  filter 
bag over the filter element.
7.  Carefully  remove  the  filter 
element  and  close  the  pro-
tective filter bag with a knot.
8.  Dispose  of  the  used  filter 
element in accordance with 
legal regulations.




Inserting the filter element:
9.  Using  the  enclosed  tool, 
attach  the  filter  holder  and 
turn it clockwise to lock it.
 
 
 
10.  Attach  the  upper  section  of 
the vacuum cleaner.
11.  Close  the  retaining  clamps 
(A).  Ensure  that  the  retain-
ing clamps fit properly.
C
D
B