7.2.6  Replacing filter element
"H" (Xtreme Clean
System)
During the following work, ensure 
that dust is not unnecessarily 
spread around, Wear a P2 breath-
ing mask.
CAUTION! In the case of asbestos 
abatement wear additional single-
use clothing.
Never use the vacuum cleaner 
without a filter.
A
A
1.  Switch off the vacuum clean-
er  and  pull  the  mains  plug 
out of the socket.
2.  Open  the  retaining  clamps 
(A)  and  remove  the  upper 
section of the vacuum clean-
er.
Removing the filter elements:
3.  Unscrew the screw and open 
filter tension part (B).
4.  Remove carefully the cas-
settes with filter elements.
5.  Place  the  protective  filter 
bag over the filter element.
6.  Carefully  remove  the  filter 
element  and  close  the  pro-
tective filter bag with a knot.
7.  Dispose  of  the  used  fil-
ter  element  in  acordance 
with 
legal 
regulations. 
 
 
 
 
Inserting the filter elements:
8.  Insert new filter elements (C) 
into the cassettes (D). 
9.  Attach the cassettes with the 
filter  elements  onto  the  up-
per  section  of  the  vacuum 
cleaner. 
10. Fix the filter tension part (B) 
and attach the screw.
 
 
 
 
 
 
 
 
 
 
B
B
B
C
D